Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add filters








Language
Year range
1.
Clinical Endoscopy ; : 221-228, 2023.
Article in English | WPRIM | ID: wpr-966649

ABSTRACT

Background/Aims@#Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is essential for the diagnosis of pancreatic cancer. The feasibility of comprehensive genomic profiling (CGP) using samples obtained by EUS-TA has been under recent discussion. This study aimed to evaluate the utility of EUS-TA for CGP in a clinical setting. @*Methods@#CGP was attempted in 178 samples obtained from 151 consecutive patients with pancreatic cancer at the Aichi Cancer Center between October 2019 and September 2021. We evaluated the adequacy of the samples for CGP and determined the factors associated with the adequacy of the samples obtained by EUS-TA retrospectively. @*Results@#The overall adequacy for CGP was 65.2% (116/178), which was significantly different among the four sampling methods (EUS-TA vs. surgical specimen vs. percutaneous biopsy vs. duodenal biopsy, 56.0% [61/109] vs. 80.4% [41/51] vs. 76.5% [13/17] vs. 100.0% [1/1], respectively; p=0.022). In a univariate analysis, needle gauge/type was associated with adequacy (22 G fine-needle aspiration vs. 22 G fine-needle biopsy [FNB] vs. 19 G-FNB, 33.3% (5/15) vs. 53.5% (23/43) vs. 72.5% (29/40); p=0.022). The sample adequacy of 19 G-FNB for CGP was 72.5% (29/40), and there was no significant difference between 19 G-FNB and surgical specimens (p=0.375). @*Conclusions@#To obtain adequate samples for CGP with EUS-TA, 19 G-FNB was shown to be the best in clinical practice. However, 19 G-FNB was not still sufficient, so further efforts are required to improve adequacy for CGP.

2.
Clinical Endoscopy ; : 367-374, 2023.
Article in English | WPRIM | ID: wpr-1000051

ABSTRACT

Background/Aims@#Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) using oblique-view EUS in patients with a surgically altered anatomy (SAA) of the upper gastrointestinal tract is limited because of difficult scope insertion due to the disturbed anatomy. This study aimed to investigate the efficiency of forward-view (FV)-EUS in performing FNA in patients with a SAA. @*Methods@#We retrospectively investigated 32 patients with a SAA of the upper gastrointestinal tract who visited Aichi Cancer Center Hospital in Nagoya, Japan, between January 2014 and December 2020. We performed-upper gastrointestinal EUS-FNA using FV-EUS combined with fluoroscopic imaging to confirm tumor recurrence or to make a decision before chemotherapy or after a failure of diagnosis by radiology. @*Results@#We successfully performed EUS-FNA in all studied patients (100% technical success), with the specificity, sensitivity, and accuracy of 100%, 87.5%, and 87.8%, respectively, with no complications. @*Conclusions@#EUS-FNA using FV-EUS combined with fluoroscopic imaging is an effective and safe technique for tissue acquisition in patients with a SAA.

3.
Clinical Endoscopy ; : 490-498, 2023.
Article in English | WPRIM | ID: wpr-1000030

ABSTRACT

Background/Aims@#Post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP) is the most common and serious complication of endoscopic retrograde cholangiopancreatography. To prevent this event, a unique precutting method, termed opening window fistulotomy, was performed in patients with a large infundibulum as the primary procedure for biliary cannulation, whereby a suprapapillary laid-down H-shaped incision was made without touching the orifice. This study aimed to assess the safety and feasibility of this novel technique. @*Methods@#One hundred and ten patients were prospectively enrolled in this study. Patients with a papillary roof size ≥10 mm underwent opening window fistulotomy for primary biliary access. In addition, the incidence of complications and success rate of biliary cannulation were evaluated. @*Results@#The median size of the papillary roof was 6 mm (range, 3–20 mm). Opening window fistulotomy was performed in 30 patients (27.3%), none of whom displayed PEP. Duodenal perforation was recorded in one patient (3.3%), which was resolved by conservative treatment. The cannulation rate was high (96.7%, 29/30 patients). The median duration of biliary access was 8 minutes (range, 3–15 minutes). @*Conclusions@#Opening window fistulotomy demonstrated its feasibility for primary biliary access by achieving great safety with no PEP complications and a high success rate for biliary cannulation.

4.
Clinical Endoscopy ; : 458-462, 2022.
Article in English | WPRIM | ID: wpr-925804

ABSTRACT

Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (HGS) is widely performed not only as an alternative to transpapillary biliary drainage, but also as primary drainage for malignant biliary obstruction. For anatomical reasons, this technique carries an unavoidable risk of mispuncturing intrahepatic vessels. We report a technique for troubleshooting EUS-guided portal vein coiling to prevent bleeding from the intrahepatic portal vein after mispuncture during interventional EUS. EUS-HGS was planned for a 59-year-old male patient with unresectable pancreatic cancer. The dilated bile duct (lumen diameter, 2.8 mm) was punctured with a 19-gauge needle, and a guidewire was inserted. After bougie dilation, the guidewire was found to be inside the intrahepatic portal vein. Embolizing coils were placed to prevent bleeding. Embolization coils were successfully inserted under stabilization of the catheter using a double-lumen cannula with a guidewire. Following these procedures, the patient was asymptomatic. Computed tomography performed the next day revealed no complications.

5.
Clinical Endoscopy ; : 596-602, 2021.
Article in English | WPRIM | ID: wpr-897733

ABSTRACT

Background/Aims@#The Japan Gastroenterological Endoscopy Society (JGES) has published guidelines for gastroenterological endoscopy in patients undergoing antithrombotic treatment. These guidelines classify endoscopic ultrasound-guided biliary drainage (EUS-BD) as a high-risk procedure. Nevertheless, the bleeding risk of EUS-BD in patients undergoing antithrombotic therapy is uncertain. Therefore, this study aimed to assess the bleeding risk in patients undergoing antithrombotic therapy. @*Methods@#This single-center retrospective study included 220 consecutive patients who underwent EUS-BD between January 2013 and December 2018. We managed the withdrawal and continuation of antithrombotic agents according to the JGES guidelines. We compared the bleeding event rates among patients who received and those who did not receive antithrombotic agents. @*Results@#A total of 18 patients (8.1%) received antithrombotic agents and 202 patients (91.8%) did not. Three patients experienced bleeding events, with an overall bleeding event rate of 1.3% (3/220): one patient was in the antithrombotic group (5.5%) and two patients were in the non-antithrombotic group (0.9%) (p=0.10). All cases were moderate. The sole thromboembolic event (0.4%) was a cerebral infarction in a patient in the non-antithrombotic group. @*Conclusions@#The rate of EUS-BD-related bleeding events was low. Even in patients receiving antithrombotic therapy, the bleeding event rates were not significantly different from those in patients not receiving antithrombotic therapy.

6.
Clinical Endoscopy ; : 596-602, 2021.
Article in English | WPRIM | ID: wpr-890029

ABSTRACT

Background/Aims@#The Japan Gastroenterological Endoscopy Society (JGES) has published guidelines for gastroenterological endoscopy in patients undergoing antithrombotic treatment. These guidelines classify endoscopic ultrasound-guided biliary drainage (EUS-BD) as a high-risk procedure. Nevertheless, the bleeding risk of EUS-BD in patients undergoing antithrombotic therapy is uncertain. Therefore, this study aimed to assess the bleeding risk in patients undergoing antithrombotic therapy. @*Methods@#This single-center retrospective study included 220 consecutive patients who underwent EUS-BD between January 2013 and December 2018. We managed the withdrawal and continuation of antithrombotic agents according to the JGES guidelines. We compared the bleeding event rates among patients who received and those who did not receive antithrombotic agents. @*Results@#A total of 18 patients (8.1%) received antithrombotic agents and 202 patients (91.8%) did not. Three patients experienced bleeding events, with an overall bleeding event rate of 1.3% (3/220): one patient was in the antithrombotic group (5.5%) and two patients were in the non-antithrombotic group (0.9%) (p=0.10). All cases were moderate. The sole thromboembolic event (0.4%) was a cerebral infarction in a patient in the non-antithrombotic group. @*Conclusions@#The rate of EUS-BD-related bleeding events was low. Even in patients receiving antithrombotic therapy, the bleeding event rates were not significantly different from those in patients not receiving antithrombotic therapy.

7.
Clinical Endoscopy ; : 60-64, 2020.
Article | WPRIM | ID: wpr-832117

ABSTRACT

Background/Aims@#Non-invasive tissue sampling from the lower intra-abdominal and pelvic cavity is challenging. The role of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in this situation is not well-established because of the limitations of the curved linear-array echoendoscopy-EUS for colonic insertion. The aim of this study was to report our institutional experience of transcolonic EUS-FNA using forward-viewing therapeutic linear echoendoscopy-EUS (FV-EUS) in combination with fluoroscopic guidance. @*Methods@#Medical records of 13 patients who underwent transcolonic EUS-FNA of extracolonic lesions using FV-EUS in combination with fluoroscopic guidance at Aichi Cancer Center Hospital, Nagoya, Japan from June 2015 to November 2018 were retrospectively reviewed. @*Results@#Using FV-EUS under fluoroscopic guidance, the FNA procedure could be performed successfully in all patients (100% technical success), with a median procedure time of 31 minutes. The sensitivity, specificity, and accuracy of EUS-FNA for detecting malignant lesions in this study were 91%, 100%, and 92%, respectively. There were no adverse events associated with the EUS-FNA procedure. @*Conclusions@#FV-EUS in combination with fluoroscopic guidance is an easy, safe, and effective technique for FNA of extracolonic lesions in the lower abdomen.

8.
Gastrointestinal Intervention ; : 40-43, 2018.
Article in English | WPRIM | ID: wpr-739757

ABSTRACT

SUMMARY OF EVENT: Bacterial, mycotic peritonitis and Candida fungemia developed in a patient with moderate ascites who had undergone endoscopic ultrasound-guided biliary drainage (EUS-BD). Antibiotics and antifungal agent were administered and ascites drainage was performed. Although the infection improved, the patient's general condition gradually deteriorated due to aggravation of the primary cancer and he died. TEACHING POINT: This is the first report to describe infectious peritonitis after EUS-BD. Ascites carries the potential risk of severe complications. As such, in patients with ascites, endoscopic retrograde cholangiopancreatography (ERCP) is typically preferred over EUS-BD or percutaneous drainage to prevent bile leakage. However, ERCP may not be possible in some patients with tumor invasion of the duodenum or with surgically altered anatomy. Thus, in patients with ascites who require EUS-BD, we recommend inserting the drainage tube percutaneously and draining the ascites before and after the intervention in order to prevent severe infection.


Subject(s)
Humans , Anti-Bacterial Agents , Ascites , Bile , Candida , Cholangiopancreatography, Endoscopic Retrograde , Drainage , Duodenum , Endosonography , Fungemia , Peritonitis
9.
Gastrointestinal Intervention ; : 82-84, 2017.
Article in English | WPRIM | ID: wpr-198942

ABSTRACT

SUMMARY OF EVENT: Pneumoderma, mediastinal emphysema, and bilateral pneumothorax were developed in the patient who had undergone transesophageal endoscopic ultrasonography-guided rendezvous technique. Chest drainage was performed immediately. TEACHING POINT: Transesophageal approach carries the potential risks of severe complications such as mediastinal emphysema, mediastinitis, and pneumothorax. To prevent puncturing through the esophagus, clipping the esophagogastric junction using a forward-viewing scope before procedure is very useful. In cases of inadvertent transesophageal puncture, devices other than the needle should not be passed through the site.


Subject(s)
Humans , Drainage , Endosonography , Esophagogastric Junction , Esophagus , Mediastinal Emphysema , Mediastinitis , Needles , Pneumothorax , Punctures , Thorax
10.
Gastrointestinal Intervention ; : 216-220, 2016.
Article in English | WPRIM | ID: wpr-184912

ABSTRACT

BACKGROUND: Both endoscopic ultrasound-guided celiac plexus neurolysis (EUS-CPN) and tumor ablation using ethanol are very common procedures, and the utility of these therapies has already been reported in prominent journals. However, their effectiveness appears temporary and insufficient, especially EUS-CPN. We therefore have to consider new reagents for improving the results. The present study examined the best concentration of ethanol and povidone iodine mixed with atelocollagen for more effective therapies. METHODS: The effects of the new reagents were confirmed in three live pigs. At first, we injected three kinds of reagents (including indigo carmine) in three separate areas of para-aortic tissue under EUS guidance in one pig. At more than 4 hours after injection, we checked ethanol injection sites after dissection. In next study, we performed EUS-guided injection of a total of six kinds of reagents (two kinds of ethanol, three kinds of povidone iodine, and control atelocollagen) into the livers of two living pigs. After 2 weeks, we examined tissue damage to the liver in the two pigs. RESULTS: The 75% ethanol (absolute ethanol 3.75 mL + 1% atelocollagen 1.25 mL + a very small amount of indigo carmine) was seen like blue gel, and still remained in the para-aortic tissue. Brownish areas of povidone iodine mixed with 3% atelocollagen exhibited clear, regular borders with greatly reduced infiltration into surrounding tissue compared to others. CONCLUSION: We concluded that 75% ethanol mixed with 1% atelocollagen appears optimal for EUS-CPN. Povidone iodine mixed with 3% atelocollagen may be suitable for small tumor ablation therapy.


Subject(s)
Celiac Plexus , Endoscopic Ultrasound-Guided Fine Needle Aspiration , Endosonography , Ethanol , Indicators and Reagents , Indigo Carmine , Liver , Povidone-Iodine , Swine
SELECTION OF CITATIONS
SEARCH DETAIL